Rectifier reverse VR-300

Purpose
The VR-300 reversible rectifier is designed for power supply from the three-phase network of the technological equipment (platingbaths, water treatmentsystems, etc.) by direct voltage with polarity alternation. TheVR-300 rectifier operation mode is long-term irrespective of the load operation mode when being powered from the external network. TheVR-300 reversible rectifierfulfils following additional functions:
  • stepwise regulation of the output voltage within assigned range;
  • regulation of operation time and pause;
  • issue of commands “Operation”, “Electromagnetic valve control” and :Emergency”;
  • electronic protection of short circuitin load;
  • indication of work modes;
  • digital indication of output current and voltage as well as time of work and pause;
  • possibility of remote controlя;
  • direct current-based galvanic decoupling between input network and output with electrical strength 1500Vduring 1 min.

Technical Characteristisc

 Parameter Value
 Rated input voltage, V; Hz   3-phase 380/220; 50
 Maximum consumed power from network, kVa   11,0
 Output voltage range, В   =20…80*
 Number of stages   7
 Maximum load current (at output voltage up to 33 V), А  300
 Range of regulation of operating time, s.  10...99
 Pause time adjustment range, s.  5...99
 Maximum current of signal contacts, А  10
 Minimal efficiency  90%
Minimal insulation resistance, МОhm 5,0
Minimal inlet cable section, мм2 5х1,5
Minimal outlet cable section, мм2 2х95
Maximal overall dimensions of the cabinet (WхHхD), mm 600х1470х410
Maximal mass, kg 170,0


Output parameters of the rectifier


 № step Voltage, В  Maximum current, А 
  I   24±3   300
  II   32±3   300
  III   38±3   260
  IV   45±3   220
  V   52±3   190
  VI   66±4   150
  VII   78±4   125


Design

TheVR-300 reversible rectifieris arranged according to the modular principle in the form of installed on floor metal cabinet (Figure 1). VR-300 reversiblerectifier(1). Frontupperfalsepanelcomprisesautomaticbreaker “NETWORK”, switch “CONTROL 1-2”, digitalindicatorsandcontrols(2). Front middle false panel, under which the cabinet screw terminal blocks for connection to the network and to the load are located (3). Front lower false panel of the cabinet, under which three-phase transformers are (4). Upper panel of the cabinet, on which fittings for cables are located (5).
vr300.jpg

vr3002.jpg

Diagram of the VR-300 reversible rectifier operation

Оформите заявку на расчет
X
Напишите ниже о проблеме, возникшей с нашим оборудованием
{{ ELEMENTS.length }}
{{ DATA.TOTAL_SUM }} р.
: {{ item.MODEL }}
{{ item.STATUS }}
{{ item.NALICHIE }}
{{ item.PRICE }}
{{ item.OLD_PRICE }}
- +
: {{ DATA.TOTAL_DISCOUNT_SUM }}
: {{ DATA.TOTAL_SUM }}

Наверх